Your firm failed to establish laboratory controls that include scientifically sound and appropriate specifications, standards, sampling plans, and test procedures designed to assure that components, drug product containers, closures, in-process materials, labeling, and drug products conform to appropriate standards of identity, strength, quality, and purity (21 CFR 211.160(b)). Your firm failed to perform method validation (or verification, as appropriate) of test methods to…
Inspection Record
Glenmark Pharmaceuticals Limited — FDA Warning Letter Findings
View the regulator's official source The source document is always the basis for judgement.
Findings
Your firm failed to thoroughly investigate any unexplained discrepancy or failure of a batch or any of its components to meet any of its specifications, whether or not the batch has already been distributed (21 CFR 211.192). A. There were several dissolution failures for potassium chloride extended-release (ER) capsules during stability testing. One of the potential root causes you described was the occasional “ (b)(4) ” of your incoming active pharmaceutical ingredient…
Your firm failed to follow an adequate written testing program designed to assess the stability characteristics of drug products (21 CFR 211.166(a)). You failed to follow your written stability procedure for your finished drug products. For example, you did not complete timely stability testing for approximately (b)(4) stability samples for U.S. commercial drug products within the stipulated timeline ( (b)(4) after sample pull). Stability testing was overdue by 3 months or…
About this record
Extracted automatically from the document US FDA published on 2025-07-22. The source is available at the link above.
This is a record of that moment. Inspection findings are usually followed by the company's response and corrective action, but this page does not know how that turned out. Do not read it as the current state; check the regulator's official announcements for the latest status.
Translation and classification are automated and may differ in nuance from the source.