Your firm failed to ensure that laboratory records included complete data derived from all tests necessary to ensure compliance with established specifications and standards (21 CFR 211.194(a)). Your firm failed to collect the required amount of environmental and personnel monitoring samples required by your procedures to support the manufacture of sterile drug products. During the inspection, a reconciliation of samples that should have been taken during manufacturing…
Inspection Record
Kilitch Healthcare India Limited — FDA Warning Letter Findings
View the regulator's official source The source document is always the basis for judgement.
Findings
Your firm failed to perform operations within specifically defined areas of adequate size and to have separate or defined areas or such other control systems necessary to prevent contamination or mix-ups in aseptic processing areas (21 CFR 211.42(c)(10)). Environmental Monitoring Deficiencies Your environmental monitoring (EM) program is deficient. Locations selected for EM in critical areas such as the ISO 5 aseptic processing line, do not have scientific justification to…
Your firm’s quality control unit failed to exercise its responsibility to ensure drug products manufactured are in compliance with CGMP, and meet established specifications for identity, strength, quality, and purity (21 CFR 211.22). Your firm’s QU failed to adequately execute its responsibilities. For example: A. Your QU failed to follow approved, written production and process controls. Your firm was manufacturing Multi Action Relief Drops, Polyvinyl Alcohol 0.5%, Povidone…
About this record
Extracted automatically from the document US FDA published on 2024-04-09. The source is available at the link above.
This is a record of that moment. Inspection findings are usually followed by the company's response and corrective action, but this page does not know how that turned out. Do not read it as the current state; check the regulator's official announcements for the latest status.
Translation and classification are automated and may differ in nuance from the source.