Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.
Inspection Record
Nubratori, Inc — FDA 483 Findings
Inspectors Lucila B NwatuThe inspectors who signed the published document.Inspector lookup
View the regulator's official source The source document is always the basis for judgement.
Findings
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Your outsourcing facility has not submitted a report to FDA identifying a product compounded during the previous six months as required by section 503B(b)(2)(A) of the Federal Food, Drng, and Cosmetic Act (FD&C Act).
Each lot of a component liable to objectionable microbiological contamination is deficiently subjected to microbiological tests before use.
Establishment of the reliability of the component supplier's report of analyses is deficient in that the test results are not appropriately validated at appropriate intervals.
About this record
Extracted automatically from the document US FDA published on 2024-08-08. The source is available at the link above.
This is a record of that moment. Inspection findings are usually followed by the company's response and corrective action, but this page does not know how that turned out. Do not read it as the current state; check the regulator's official announcements for the latest status.
Translation and classification are automated and may differ in nuance from the source.