There are some specific risks associated with SUS which should be assessed as part of the CCS. These risks include but are not limited to:

i. The interaction between the product and product contact surface (such as adsorption, or leachables and extractables).

ii. The fragile nature of the system compared with fixed reusable systems.

iii. The increase in the number and complexity of manual operations (including inspection and handling of the system) and connections made.

iv. The complexity of the assembly.

v. The performance of the pre- and post-use integrity testing for sterilising grade filters (see paragraph 8.87).

vi. The risk of holes and leakage.

vii. The potential for compromising the system at the point of opening the outer packaging.

viii. The risk of particle contamination.