ICH

ICH Q7 2.22

2. QUALITY MANAGEMENT

Section text

The main responsibilities of the independent quality unit(s) should not be delegated. These responsibilities should be described in writing and should include but not necessarily be limited to:

1. Releasing or rejecting all APIs. Releasing or rejecting intermediates for use outside the control of the manufacturing company;

2. Establishing a system to release or reject raw materials, intermediates, packaging and labelling materials;

3. Reviewing completed batch production and laboratory control records of critical process steps before release of the API for distribution;

4. Making sure that critical deviations are investigated and resolved;

5. Approving all specifications and master production instructions;

6. Approving all procedures impacting the quality of intermediates or APIs;

7. Making sure that internal audits (self-inspections) are performed;

8. Approving intermediate and API contract manufacturers;

9. Approving changes that potentially impact intermediate or API quality;

10. Reviewing and approving validation protocols and reports;

11. Making sure that quality related complaints are investigated and resolved;

12. Making sure that effective systems are used for maintaining and calibrating critical equipment;

13. Making sure that materials are appropriately tested and the results are reported;

14. Making sure that there is stability data to support retest or expiry dates and storage conditions on APIs and/or intermediates where appropriate; and

15. Performing product quality reviews (as defined in Section 2.5).

Source: International Council for Harmonisation (ICH) · © ICH. Per the legal notice in each guideline, the document may be used, reproduced and distributed provided ICH's copyright is acknowledged; any adaptation or translation must be labelled as such and must not imply ICH endorsement. · retrieved 2026-11-15

Weekly Newsletter

Get new findings like these every Monday

Every Monday we email the week's new findings and actions from the FDA, EMA, Health Canada and MFDS. Each one links to its record on our site, where you'll find the regulator's original document. We'll also let you know when the site gains new features. Unsubscribe any time with one click.

See recent findings first

Sent every Monday · a confirmation email follows when you subscribe · unsubscribe from the footer of any email.