Records should be maintained including:

- The name of the manufacturer, identity and quantity of each shipment of each batch of raw materials, intermediates or labelling and packaging materials for API's; the name of the supplier; the supplier's control number(s), if known, or other identification number; the number allocated on receipt; and the date of receipt;

- The results of any test or examination performed and the conclusions derived from this;

- Records tracing the use of materials;

- Documentation of the examination and review of API labelling and packaging materials for conformity with established specifications; and

- The final decision regarding rejected raw materials, intermediates or API labelling and packaging materials.

Source: International Council for Harmonisation (ICH) · © ICH. Per the legal notice in each guideline, the document may be used, reproduced and distributed provided ICH's copyright is acknowledged; any adaptation or translation must be labelled as such and must not imply ICH endorsement. · retrieved 2026-11-15