Laboratory controls do not include the establishment of scientifically sound and appropriate sampling plans and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
The quality control unit lacks authority to review production records to assure that no errors have occurred.
There is no written testing program designed to assess the stability characteristics of drug products.
Clothing of personnel engaged in the manufacturing, processing, packing and holding of drug products is not appropriate for the duties they perform.
There is a lack of written procedures describing in sufficient detail the receipt, identification, storage, handling, sampling, examination and testing of labeling and packaging materials.
Approved components, drug product containers and closures are not retested or reexamined as appropriate for identity, strength, quality and purity after exposure to conditions that might have an adverse effect with subsequent approval or rejection by the quality control unit.
Drug product containers and closures were not clean and sterilized and processed to remove pyrogenic properties to assure that they are suitable for their intended use.
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.
Container closure systems do not provide adequate protection against foreseeable external factors in storage and use that can cause deterioration or contamination of the drug product.
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Procedures designed to assure that correct labels, labeling and packaging materials are used for drug products are not written.
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release.