Auro Pharmacies, Inc. — FDA 483 Findings

US FDAInspected 2017-01-20Published 2024-01-17 14 findingsAseptic processing and sterility assuranceLaboratory and QC controlsTraining and personnelDeviation, CAPA, and investigationContamination controlMaterial and supplier controlQuality unit oversightStability and storage

View the regulator's official source The source document is always the basis for judgement.

Findings

1Aseptic processing and sterility assurance

Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

2Aseptic processing and sterility assurance

Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.

3Laboratory and QC controls

Laboratory controls do not include the establishment of scientifically sound and appropriate sampling plans and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.

4Aseptic processing and sterility assurance

Drug product containers and closures were not clean and sterilized and processed to remove pyrogenic properties to assure that they are suitable for their intended use.

5Aseptic processing and sterility assurance

Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.

6Training and personnel

Clothing of personnel engaged in the manufacturing, processing, packing and holding of drug products is not appropriate for the duties they perform.

7Deviation, CAPA, and investigation

Written records are not always made of investigations into unexplained discrepancies.

8Contamination control

Container closure systems do not provide adequate protection against foreseeable external factors in storage and use that can cause deterioration or contamination of the drug product.

9Laboratory and QC controls

Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the finall specifications prior to release.

10Material and supplier control

There is a lack of written procedures describing in sufficient detail the receipt, identification, storage, handling, sampling, examination and testing of labeling and packaging materials.

11Quality unit oversight

Approved components, drug product containers and closures are not retested or reexamined as appropriate for identity, strength, quality and purity after exposure to conditions that might have an adverse effect with subsequent approval or rejection by the quality control unit.

12Stability and storage

There is no written testing program designed to assess the stability characteristics of drug products.

13Material and supplier control

Procedures designed to assure that correct labels, labeling and packaging materials are used for drug products are not written.

14Quality unit oversight

The quality control unit lacks authority to review production records to assure that no errors have occurred.

About this record

Extracted automatically from the document US FDA published on 2024-01-17. The source is available at the link above.

This is a record of that moment. Inspection findings are usually followed by the company's response and corrective action, but this page does not know how that turned out. Do not read it as the current state; check the regulator's official announcements for the latest status.

Translation and classification are automated and may differ in nuance from the source.

Other records for this company

Auro Pharmacies, Inc. company profile — full history US FDA documents, 2024 Go to Findings search