Your firm does not perform environmental monitoring for microorganisms.
Inspection Record
Vital Rx, Inc. dba Atlantic Pharmacy and Compounding — FDA 483 Findings
Inspectors Joanne E. KingThe inspectors who signed the published document.Inspector lookup
View the regulator's official source The source document is always the basis for judgement.
Findings
Hazardous and highly potent drugs were prepared and handled without providing adequate cleaning of work surfaces and reusable equipment such as spateulas, beakers, and <Redac te d B4> jar s to prevent cross-contamination.
Your firm failed to perform adequate media fill studies in that they did not closely simulate aseptic operations incorporating as appropiate, worst-case activities and conditions that provide a challenge to aseptic operations.
You do not have a sporicidal agent for cleaning your ISO 5 laminar flow hood