ISO-5 classified areas were not certified under dynamic conditions.
Inspection Record
Option Care Enterprises Inc. — FDA 483 Findings
View the regulator's official source The source document is always the basis for judgement.
Findings
There is no record for monitoring of pressure differentials between adjacent rooms in the Compounding Area and no record for cleaning when drugs were produced on the weekends.
Placement and/or use of non-sterile material within the ISO 5 area.
Your media plates for environmental monitoring and personnel monitoring were not incubated appropriately to ensure your production process and production facility do not have insanitary conditions and that they are suitable for sterile drug production Specifically,
A non-sterile tool was used in the production of drugs.
Disinfecting agents used in the ISO 5 area are not sterile.
Apparent rust/discoloration was observed in the ISO 5 area.
There is no cleaning of the dust-collecting areas in the area surrounding the ISO 5 area.
Similar findings at other companies
GRM selected findings from the same type of public document whose wording is close to a finding in this document. One per company.
A record as of the US FDA document published on 2024-01-17. Check the agency's announcements for any later corrective action, and rely on the original text. Translation and classification are machine-made.