a) The instructions to add antifoam in the production bioreactor are unclear and open to operator interpretation.
Inspection Record
GH Genhelix, S.A. — FDA 483 Findings
Inspectors Arsen KarapetyanThe inspectors who signed the published document.Inspector lookup
View the regulator's official source The source document is always the basis for judgement.
Findings
The responsibilities and procedures applicable to the quality control are not in writing and fully followed.
Equipment used in the manufacture and processing of a drug substance shall be suitably located to facilitate operations for its intended use.
Class D area cleaning is inadequate.
Material Management is inadequate.
Drug Substance filling is inadequate.
Cell Bank Storage is inadequate.
havens cleaning is inadequate.
Written records of investigations into unexplained discrepancies do not always include conclusions and follow-up which are adequately justified.
Similar findings at other companies
GRM selected findings from the same type of public document whose wording is close to a finding in this document. One per company.
- SURETEC INNOVATIONS LLC2026-03-05 · US FDASimilar to finding 2 The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
- RayzeBio, Inc2026-02-24 · US FDASimilar to finding 2 The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
- Shimoga Chemicals2026-01-23 · US FDASimilar to finding 2 The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
- Lantheus Medical Imaging, Inc.2026-04-09 · US FDASimilar to finding 2 The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
- VitaCare Labs Inc.2025-05-16 · US FDASimilar to finding 9 Written records of investigations into unexplained discrepancies do not always include the conclusions and follow-up.
A record as of the US FDA document published on 2026-10-23. Check the agency's announcements for any later corrective action, and rely on the original text. Translation and classification are machine-made.