Inspection Record

H & P Industries, Inc. — FDA 483 Findings

US FDAInspected 2015-07-11Published 2024-01-17 17 findingsMaterial and supplier controlDeviation, CAPA, and investigationOther quality systemContamination controlComputer system validationLabeling and packagingEquipment and facilityTraining and personnelProcess validationQuality unit oversight

Inspectors Marie A Fadden · Joel D. Hustedt · Sandra A. HughesThe inspectors who signed the published document.Inspector lookup

View the regulator's official source The source document is always the basis for judgement.

Findings

1Material and supplier control

Rejected in-process materials are not identified and controlled under a quarantine system to prevent their use in manufacturing or processing operations for which they are unsuitable.

2Deviation, CAPA, and investigation

Investigations ofa failure ofa batch or any ofits components to meet any of its specifications did not extend to other batches ofthe same drug product..

3Other quality system

The number ofcontainers to be sampled is not based upon appropriate criteria.

4Contamination control

Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established.

5Computer system validation

Records ofthe inspections ofautomatic, mechanical or electronic equipment, including computers or related systems are not maintained.

6Material and supplier control

Reports ofanalysis from component suppliers are accepted in lieu oftesting each component for conformity with all appropriate written specifications, without establishing the reliability ofthe supplier's analyses through appropriate validation ofthe supplier's test results at appropriate intervals.

7Labeling and packaging

Strict control is not exercised over labeling issued for use in drug product labeling operations.

8Equipment and facility

Written procedures are not followed for the cleaning and maintenance ofequipment, including utensils, used in the manufacture, processing, packing or holding ofa drug product.

9Equipment and facility

Written procedures for cleaning and maintenance fail to include description in sufficient detail ofmethods, equipment and materials used and description in sufficient detail ofthe methods ofdisassembling and reassembling equipment as necessary to assure proper cleaning and maintenance.

10Training and personnel

GMP training is not conducted with sufficient frequency to assure that employees remain familiar with CGMP requirements applicable to them.

11Equipment and facility

Equipment used in the manufacture, processing, packing or holding ofdrug products is not ofappropriate design to facilitate operations for its intended use and cleaning and maintenance.

12Process validation

Control procedures are not established which validate the performance ofthose manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.

13Deviation, CAPA, and investigation

Deviations from written specifications are not justified.

14Quality unit oversight

Reprocessing was performed without the approval ofthe quality control unit.

15Other quality system

The use of instruments not meeting established specifications was observed.

16Equipment and facility

All major equipment used during the production ofa batch ofdrug product is not properly identified at all times to indicate contents.

17Equipment and facility

Equipment and utensils are not maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity ofthe drug product.

About this record

Extracted automatically from the document US FDA published on 2024-01-17. The source is available at the link above.

This is a record of that moment. Inspection findings are usually followed by the company's response and corrective action, but this page does not know how that turned out. Do not read it as the current state; check the regulator's official announcements for the latest status.

Translation and classification are automated and may differ in nuance from the source.