Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Inspection Record
Pyramid Laboratories, Inc. — FDA 483 Findings
Inspectors Jennifer M. Gogley · Caryn M. McnabThe inspectors who signed the published document.Inspector lookup
View the regulator's official source The source document is always the basis for judgement.
Findings
The accuracy, sensitivity, and specificity oftest methods have not been established.
Written records are not always made of investigations into unexplained discrepancies.
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate vvritten specifications, without establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.
Time limits are not established when approp1iate for the completion ofeach production phase to assure the quality of the drug product.
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
The quality control unit lacks responsibility to approve and reject all procedures or specifications impacting on the identity, strength, quality, and purity of drug products.
The quality control unit lacks authority to fully investigate errors that have occurred.
Written records of major equipment use are not included in individual equipment logs.
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Employees are not given training in the particular operations they perform as part of their function.