The temperature and/or humidity control was inadequate.
Inspection Record
Isologic Innovative Radiopharmaceuticals of Ontario Limited — Health Canada Inspection Findings
View the regulator's official source The source document is always the basis for judgement.
Findings
The investigation, handling, and/or reporting of test results that were out-of-specification was inadequate.
The company did not design or maintain the premises and equipment to minimize microbial contamination and the number of airborne particles in clean areas.
The change control system was inadequate for ensuring changes are properly documented, evaluated, and/or approved.
The calibration, inspection, and/or qualification of the equipment, including computerized systems, was inadequate.
The qualification and/or verification of utilities and/or support systems was inadequate.
The sampling procedure was inadequate for microbiological monitoring in processing areas or aseptic areas.
Investigations into deviations, reports, and/or follow-up actions were inadequate.
The company's cleaning of the premises and the equipment in aseptic areas was inadequate.
The company did not validate the sterility test of the finished product.