Inspection prep notes · Sterility and contamination control
Cross-contamination and cleaning validation
Also called: cross-contamination, cleaning validation
FDA looks less at whether a cleaning procedure exists than at whether it has been shown to actually remove residue from equipment. The findings below are quoted from warning letters and FDA 483s.
What inspectors cited
1Cleaning of shared equipment was not validated
Your firm also failed to validate your cleaning processes for non-dedicated equipment used to manufacture your OTC drug products.
FDA Warning Letter · Woodbine Products Company Inc. · 2026-08-04 · View document
You have not completed equipment cleaning validation studies to validate equipment cleaning SOP #10, Cleaning and Sanitization Procedure Packaging Room and Equipment, effective date 02/01/2024 which is used for the cleaning of shared equipment used in the packaging of the drug products [redacted] and [redacted] as well as several [redacted] products.
FDA 483 · Paxeuticals LLC · 2026-10-27 · View document
2Residue was left on equipment and in the work area
For example, our investigator observed stagnant (b)(4) product residue inside the tubing on the filling line with residue accumulating in crevices and on surfaces that come into direct contact with the drug product.
FDA Warning Letter · Lico Industries, LLC., d.b.a. American Towelette Company · 2026-08-11
On 01/06/2026 dispensing bay was observed with remains of apparent white powder residue on the walls, floor, and on the dust snorkel which sits above the product being weighed out.
FDA 483 · GOJO Industries LLC · 2026-10-23 · View document
3Dirty and clean hold times for equipment were not supported by studies
Yet, you have not performed a Clean Hold Time (CHT) and Dirty Hold Time Study (DHT) after (as worst-case molecule in 2022) and (as worst-case molecule in 2023-2024) as required per SOP # UNIT PR/SOP/0017-02 “Cleaned and Dirty Equipment Hold Time, effective date 03/08/2026” as introduction of new product at the site.
FDA 483 · Shilpa Medicare Limited · 2026-10-22 · View document
You established a clean hold time (CHT) of [redacted] and a dirty hold time (DHT) o [redacted] for equipment without performing adequate studies to support the CHT and DHT.
FDA 483 · Blossom Pharmaceuticals · 2026-10-22 · View document
4Beta-lactam products were not separated from other products
You failed to ensure complete and comprehensive separation of cephalosporin and (b)(4) drug products in this shared facility.
FDA Warning Letter · Baxter International Inc. · 2026-10-20 · View document
Specifically, Your firm failed to have separate dedicated facilities to prevent cross contamination of non-penicillin beta-lactam drug products that are repackaged in the same facility as non-beta-lactam drug products.
FDA 483 · Pine Pharmaceuticals, LLC · 2025-02-12 · View document
5Cleaning records did not show what was done or when it was verified
In addition, you failed to adequately document the type of cleaning performed or the specific cleaning agent used to clean your equipment that is shared to manufacture both your OTC drug products and cosmetics.
FDA Warning Letter · Stream2Sea, LLC · 2026-09-29 · View document
Multiple instances were observed on your cleaning records where the QA verifier initialed and dated the cleaning records days after the cleaning operations were performed.
FDA 483 · LeeSar Inc · 2026-11-05 · View document
Questions to check against your procedures
- Has a cleaning validation study been completed for each piece of shared equipment used for more than one product?
- Are the inside of tubing, crevices and product-contact surfaces free of residue after equipment has been cleaned?
- Are the walls, floor and dust extraction arm of the dispensing area free of powder residue?
- Are the clean hold time and dirty hold time supported by studies, and were the studies repeated when a new product was introduced?
- Are beta-lactam products handled in dedicated facilities separate from other products?
- Do cleaning records show the type of cleaning and the cleaning agent used, and does the verifier sign and date them at the time of the work?