Findings

1Aseptic processing and sterility assurance

Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters lmder positive pressure.

2Laboratory and QC controls

Testing and release of drug product for distribution do not include appropriate laboratory detetmination of satisfactory conformance to the identity and strength of each active ingredient prior to release.

3Aseptic processing and sterility assurance

Procedures designed to prevent microbiological contamination of drug products pmporting to be sterile are not established, written and followed.

4Labeling and packaging

The labels of your outsourcing facility's drug products are deficient.

5Aseptic processing and sterility assurance

Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.

6Deviation, CAPA, and investigation

Deviations from written production and process control procedures are not recorded andjustified.

7Aseptic processing and sterility assurance

Test procedures relative to appropriate laborat01y testing for sterility and pyrogens are not written and followed.

8Aseptic processing and sterility assurance

Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products.

9Aseptic processing and sterility assurance

Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

10Stability and storage

There is no written testing program designed to assess the stability characteristics of dm g products.

11Deviation, CAPA, and investigation

There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distribut ed.

12Equipment and facility

The building lacks adequate space for the orderly placement of equipment and materials to prevent mix-u ps between different components, drug product containers, labeling, in-process materials and drug p roducts and to prevent contamination.

About this record

Extracted automatically from the document US FDA published on 2024-01-17. The source is available at the link above.

This is a record of that moment. Inspection findings are usually followed by the company's response and corrective action, but this page does not know how that turned out. Do not read it as the current state; check the regulator's official announcements for the latest status.

Translation and classification are automated and may differ in nuance from the source.

Other records for this company

Cantrell Drug Company company profile — full history US FDA documents, 2024 Go to Findings search