The Quality Unit cannot ensure the review of all deviation reported during production prior to finial product batch | release.
Inspection Record
Granules — FDA 483 Findings
View the regulator's official source The source document is always the basis for judgement.
Findings
Laboratory control records do not include complete data derived from all tests conducted to ensure compliance with established specifications and standards, includ ing examinations andassays.
Change Control system does not evaluste and reflect all changes that may affect the production of the finished prod- uct.
The Facility design and maintenance increases the potential for contamination ofyour equipment and product.
Materials should be bandied and stored in a manner to prevent degradation, contamination, and cross-contamination.
Employee was not trained prior to conducting the cleaning ofthe Microbiology Laboratory ISO Class 8 room.
Similar findings at other companies
GRM selected findings from the same type of public document whose wording is close to a finding in this document. One per company.
A record as of the US FDA document published on 2017-01-10. Check the agency's announcements for any later corrective action, and rely on the original text. Translation and classification are machine-made.