Inspection Record

Drug Depot, LLC., dba APS Pharmacy — FDA 483 Findings

US FDAInspected 2022-06-17Published 2022-11-07 4 findingsAseptic processing and sterility assurance

Inspectors Saundrea A MunroeThe inspectors who signed the published document.Inspector lookup

View the regulator's official source The source document is always the basis for judgement.

Findings

1Aseptic processing and sterility assurance

Your firm failed to perform adequate smoke studies under dynamic conditions to demonstrate unidirectional airflow within the ISO 5 area.

2Aseptic processing and sterility assurance

Personnel conducted aseptic manipulations in an area that blocked the movement of first pass air aroun d an open unit, either before or after it was filled with sterile product.

3Aseptic processing and sterility assurance

Personnel moved rapidly in the vicinity of open sterile units and instruments, which disrupted th e airflow and increased the risk of bringing lesser quality air into the ISO 5 classified aseptic processin g area.

4Aseptic processing and sterility assurance

The ISO 5 classified aseptic processing areas had difficult to clean, particle-generating and visibly dirty equipment or smface.

About this record

Extracted automatically from the document US FDA published on 2022-11-07. The source is available at the link above.

This is a record of that moment. Inspection findings are usually followed by the company's response and corrective action, but this page does not know how that turned out. Do not read it as the current state; check the regulator's official announcements for the latest status.

Translation and classification are automated and may differ in nuance from the source.

Other records for this company

Drug Depot, LLC., dba APS Pharmacy company profile — full history US FDA documents, 2022 Go to Findings search