You produced hazardous drugs without providing adequate cleaning of work surfaces to prevent cross-contamination.
Inspection Record
Northern VA Compounders PLLC — FDA 483 Findings
Inspectors Jonathan G Matrisciano · Daniel J MinThe inspectors who signed the published document.Inspector lookup
View the regulator's official source The source document is always the basis for judgement.
Findings
Personnel conducted aseptic manipulations and placed equipment/supplies in an area that blocked the movement of first pass air around an open unit, either before or after it was filled with sterile product.
The <Redacted B4> intended to render fmal product sterile was not pharmaceutical grade.
You used a non-pharmaceutical grade component in the formulation of a drug product.
You produced beta-lactam drugs without providing adequate containment, segregation, cleaning of work surfaces, cleaning of utensils and cleaning of personnel to prevent cross-contamination.
The ISO 5 classified aseptic processing areas had difficult to clean, particle-generating and visibly dirty equipment or surface.
You had inadequate HEPA filter coverage and airflow over the area to which sterile product was exposed.
Personnel donned gowning apparel improperly, in a way that may have caused the gowning apparel to become contaminated.