Personnel infrequently changed and sanitized gloves to prevent contamination.
Inspection Record
Empower Clinic Services LCC dba Empower Pharmacy — FDA 483 Findings
Inspectors Camerson E Moore · Demario L WallsThe inspectors who signed the published document.Inspector lookup
View the regulator's official source The source document is always the basis for judgement.
Findings
Inadequate post-use <Redacted B4> testing on <Redacted B4> used to sterilize drug products.
Use of ingredients not intended for pharmaceutical use in sterile drug production.
Inadequate routine environmental monitoring in the ISO 5 area and classified areas.
Compounding with components, containers or other materials that have not been verified to assure that they do not contribute endotoxin contamination that may be objectionable given the product's intended use.
Failure to appropriately and regularly clean and disinfect or sterilize equipment located in the ISO 5 area.
Personnel were observed conducting aseptic manipulations where the movement of "first air" in the ISO 5 area is blocked or disrupted.