Findings

1Aseptic processing and sterility assurance

Personnel engaged in aseptic processing were observed wearing non-sterile gloves.

2Environmental monitoring

Inadequate routine environmental monitoring in the ISO 5 area.

3Aseptic processing and sterility assurance

Failure to conduct media fills that closely simulate aseptic production operations under the worst-case, most-challenging, and stressful conditions.

4Aseptic processing and sterility assurance

Smoke studies were not performed under dynamic conditions.

5Equipment and facility

Production areas have difficult to clean or contain porous, particle generating, or visibly duty equipment or surfaces.

6Equipment and facility

Use of a sporicidal agent in the facility's classified areas was improper.

About this record

Extracted automatically from the document US FDA published on 2025-03-28. The source is available at the link above.

This is a record of that moment. Inspection findings are usually followed by the company's response and corrective action, but this page does not know how that turned out. Do not read it as the current state; check the regulator's official announcements for the latest status.

Translation and classification are automated and may differ in nuance from the source.

Palmetto Isotopes LLC company profile — full history US FDA documents, 2025 Go to Findings search