Inspection Record

Empower Clinic Services LLC dba Empower Pharmacy — FDA 483 Findings

US FDAInspected 2025-11-14Published 2025-12-18 5 findingsEquipment and facilityContamination controlTraining and personnelAseptic processing and sterility assurance

Inspectors Camerson E Moore · Oluwasefunm AgbanigoThe inspectors who signed the published document.Inspector lookup

View the regulator's official source The source document is always the basis for judgement.

Findings

1Equipment and facility

Failure to appropriately and regularly clean and disinfect or sterilize equipment located in the ISO <Redacted B4> area.

2Contamination control

Microbial contamination was present in the ISO <Redacted B4> area.

3Training and personnel

Personnel were observed moving quickly in a critical area or in an area immediately adjacent to a critical area likely causing disruption of unidirectional airflow.

4Aseptic processing and sterility assurance

Smoke studies were inadequately performed under dynamic conditions.

5Aseptic processing and sterility assurance

Failure to conduct media fills that closely simulate aseptic production operations under the worst-case, most-challenging, and stressful conditions.

About this record

Extracted automatically from the document US FDA published on 2025-12-18. The source is available at the link above.

This is a record of that moment. Inspection findings are usually followed by the company's response and corrective action, but this page does not know how that turned out. Do not read it as the current state; check the regulator's official announcements for the latest status.

Translation and classification are automated and may differ in nuance from the source.

Other records for this company

Empower Clinic Services LLC dba Empower Pharmacy findings history — including this company's other documents US FDA documents, 2025 Go to Findings search