Employees are not trained in cleaning procedures.
Inspection Record
Zen Chemicals Pvt. Ltd — FDA 483 Findings
Inspectors Dipesh ShahThe inspectors who signed the published document.Inspector lookup
View the regulator's official source The source document is always the basis for judgement.
Findings
Equipment are not cleaned and sanitized to prevent contamination of the critical API intermediate product.
No investigations are conducted to evaluate all potential root causes ofmultiple sample results.
Qualification of equipment were not performed.
Appropriate controls governing computer acquired data and/or related systems have not been established to assure that changes and access to computerized software for the laboratory control system is accessed only by authorized personnel.