Inspection Record

Leiter's Cambrian Park Drugs, Inc. — FDA 483 Findings

US FDAInspected 2015-07-10Published 2024-01-17 15 findingsEquipment and facilityQuality unit oversightAseptic processing and sterility assuranceContamination controlProcess validationDeviation, CAPA, and investigationDocumentation and records

View the regulator's official source The source document is always the basis for judgement.

Findings

1Equipment and facility

Written procedures are lacking for the use of fumigating agents and cleaning and sanitizing agents designed to prevent the contamination of equipment, components, drug product containers, and drug products.

2Quality unit oversight

Drug product production and control records, are not reviewed and approved by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed.

3Aseptic processing and sterility assurance

Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written, and followed.

4Aseptic processing and sterility assurance

Each batch of drug product purporting to be sterile is not laboratory tested to determine conformance to such requirements.

5Aseptic processing and sterility assurance

Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

6Equipment and facility

Written calibration procedures for instruments, apparatus, gauges, and recording devices are deficient in that they do not include specific directions, schedules, limits for accuracy and precision, and provisions for remedial action if limits are not met.

7Contamination control

Protective apparel is not worn as necessary to protect drug products from contamination.

8Aseptic processing and sterility assurance

Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.

9Process validation

Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.

10Aseptic processing and sterility assurance

Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation ofthe sterilization process.

11Deviation, CAPA, and investigation

There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

12Aseptic processing and sterility assurance

Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.

13Documentation and records

The master production and control records are deficient in that they do not include a statement concerning any calculated excess of component.

14Equipment and facility

Equipment and utensils are not maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.

15Equipment and facility

The building Jacks adequate space for the orderly placement of equipment and materials to prevent mix-ups between different components, drug product containers, closures, in-process materials, and drug products and to prevent contamination.

About this record

Extracted automatically from the document US FDA published on 2024-01-17. The source is available at the link above.

This is a record of that moment. Inspection findings are usually followed by the company's response and corrective action, but this page does not know how that turned out. Do not read it as the current state; check the regulator's official announcements for the latest status.

Translation and classification are automated and may differ in nuance from the source.

Other records for this company

Leiter's Cambrian Park Drugs, Inc. company profile — full history US FDA documents, 2024 Go to Findings search