Your outsourcing facility has not submitted a report to FDA identifying product produced during the previous s months as required by section 503B(bX2XA).
Inspection Record
US Compounding, Inc. — FDA 483 Findings
View the regulator's official source The source document is always the basis for judgement.
Findings
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in~process material and the drug product.
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the equ ipment to produce aseptic conditions.
Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure.
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
There is no written testing program designed to assess the stability characteristics of drug products.
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile a re not established .
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release.
Equipment used in the manufacture, processing~ packing or holding of drug products is not of adequate size and suitably located to facilitate operations for its Specifically, Your firm employs a REDACTED (b)(4) water system for a REDACTED (b)(4) used for cleaning of instruments, beakers, and final containers/closures used in aseptic processes.
The labels of your outsourcing facility's drug products are deficient.