Odan Laboratories Ltd. — Health Canada Inspection Findings

Health CanadaInspected 2024-03-12 12 findingsOther quality systemEquipment and facilityQuality unit oversightDeviation, CAPA, and investigationStability and storageLaboratory and QC controlsContamination controlComputer system validation

View the regulator's official source The source document is always the basis for judgement.

Findings

1Other quality system

The receipt, preparation, and/or handling of reagents and culture media was inadequate.

2Equipment and facility

Evaluation of production processes, equipment, and/or materials was inadequate.

3Equipment and facility

The maintenance of the premises was inadequate.

4Equipment and facility

The availability, content and/or maintenance of the quality agreements between the supplier, fabricator, tester, packager, labeller, distributor, importer, and/or wholesaler was inadequate. The assessment of the contractor's competencies by the fabricator, packager/labeller, distributor, or importer was inadequate.

5Quality unit oversight

The annual product quality review procedure was inadequate.

6Deviation, CAPA, and investigation

Investigations into deviations, reports, and/or follow-up actions were inadequate.

7Stability and storage

The temperature and/or humidity control was inadequate. The guidelines and/or procedures were inadequate in ensuring storage and/or transportation conditions would maintain the quality and safe distribution of the drug.

8Laboratory and QC controls

The quality control department did not undertake all of the required activities.

9Contamination control

The sanitation programs were not adequately designed to identify and/or reduce the risks of contamination.

10Deviation, CAPA, and investigation

The investigation, handling, and/or reporting of test results that were out-of-specification was inadequate.

11Computer system validation

The calibration, inspection, and/or qualification of the equipment, including computerized systems, was inadequate.

12Other quality system

The controls were inadequate for creating, modifying, reviewing, storing, and/or retrieving records.

About this record

Extracted automatically from the document of the Health Canada inspection on 2024-03-12. The source is available at the link above.

This is a record of that moment. Inspection findings are usually followed by the company's response and corrective action, but this page does not know how that turned out. Do not read it as the current state; check the regulator's official announcements for the latest status.

Translation and classification are automated and may differ in nuance from the source.

Other records for this company

Odan Laboratories Ltd. company profile — full history Health Canada documents, 2024 Go to Findings search