Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.
See every finding in this document View the regulator's official sourceBy Category
US FDA Aseptic processing and sterility assurance findings
by this agency in this category 3,385 findings drawn from 1,212 published documents. The most recent cases are below; the full set is in search.
See all US FDA Aseptic processing and sterility assurance findingsCompanies with the most findings
Recent findings
Aseptic processing areas deficient regarding system for monitoring environmental conditions.
See every finding in this document View the regulator's official sourceProcedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed.
See every finding in this document View the regulator's official sourceProcedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed.
See every finding in this document View the regulator's official sourceThe phlebotomy site is not prepared by a method that gives maximum assurance of a sterile container of Whole Blood.
View the regulator's official sourceYour firm failed to perform adequate airflow visualization studies under dynamic conditions to demonstrate unidirectional airflow within the ISO 5 area. Your airflow visualization studies are deficient because: a. The studies do not clearly demonstrate that the airflow pattern sweeps over and away from the critical areas near and on the ISO 5 classified LAF hood work surface where aseptic operations occur. Instead, the smoke appears to arc out of the hood significantly higher than the critical area and then travel up toward the ceiling in the surrounding ISO 7 classified area. b. In your most recent airflow visualization study VAL-25-044-FR, you indicated that (b)(4) people are allowed in ISO 7 (b)(4) Room (b)(4) during aseptic operations; however, the smoke study videos provided during the FDA inspection only include a maximum of (b)(4) people, and fail to demonstrate that airflow patterns inside the ISO 5 classified critical areas are not impacted by a large number of personnel moving inside cleanroom Room (b)(4) . The FDA investigator also collected evidence indicating CGMP violations at your facility, that caused your drug products to be adulterated within the meaning of section 501(a)(2)(B) of the FDCA. The violations include, for example…
See every finding in this document View the regulator's official sourceOther agencies
These findings are a record of the moment each document was published. Inspection findings are usually followed by the company's response and corrective action, but this page does not know how that turned out — do not read them as the current state; check the regulator's official announcements for the latest status. Counts are measured from public data as of 2026-10-20, and findings are extracted automatically from the regulator's published documents. “View official source” on each case links directly to that document.