Findings

1Aseptic processing and sterility assurance

Test procedures relative to appropriate laboratory testing for sterility are not followed.

2Training and personnel

Clothing of personnel engaged in the manufacturing, processing and packing of drug products is not a ppropriate for the duties they perform.

3Other quality system

DE PARTMENT OF HEALTH AND HUMAN SERVI CES D ISTRICT ADDRESS AND PHONE NUMBER OATE(S) OF INSPECTION 6751 Steger Drive 3/27/201 7 - 3/31/201 7 - 3097 3011967886 (513)679- 2700 Fax : (513)679- 2772 SUED Raymond R.

4Deviation, CAPA, and investigation

There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any o f its components to meet any of its specifications whether or not the batch has been already distributed.

5Laboratory and QC controls

Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strengt h, quality and purity.

6Laboratory and QC controls

The accuracy and reproducibility of test methods have not been established and documented.

7Aseptic processing and sterility assurance

Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and written.

8Laboratory and QC controls

Each batch of drug product purporting to be pyogen-free is not laboratory tested to determine conformance to such requirements.

9Aseptic processing and sterility assurance

Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

About this record

Extracted automatically from the document US FDA published on 2024-01-17. The source is available at the link above.

This is a record of that moment. Inspection findings are usually followed by the company's response and corrective action, but this page does not know how that turned out. Do not read it as the current state; check the regulator's official announcements for the latest status.

Translation and classification are automated and may differ in nuance from the source.

Other records for this company

RC Outsourcing LLC findings history — including this company's other documents US FDA documents, 2024 Go to Findings search