Inspection Record

Houston Rx LLC — FDA 483 Findings

US FDAInspected 2026-08-28Published 2026-10-01 14 findingsAseptic processing and sterility assuranceOther quality systemStability and storageEquipment and facilityContamination controlCleaning validation

View the regulator's official source The source document is always the basis for judgement.

Findings

1Aseptic processing and sterility assurance

Sterile drugs were exposed to lower than ISO 5 quality air.

2Aseptic processing and sterility assurance

Use of ingredients not intended for pharmaceutical use in sterile drug production.

3Aseptic processing and sterility assurance

Sterile products were exposed to non-sterile or non-depyrogenated supplies.

4Other quality system

Inadequate <Redacted B4> testin g on <Redacted B4> used to sterilize drug products.

5Stability and storage

Your firm is not storing active pharmaceutical ingredients (API) per the labeled storage conditions.

6Other quality system

A pattern of frequent or acute pressure reversals was observed from areas of less clean air to areas of higher air cleanliness.

7Aseptic processing and sterility assurance

Failure to conduct media fills that closely simulate aseptic production operations under the worst-case, most-challenging, and stressful conditions.

8Equipment and facility

The facility is designed and/or operated in a way that permits poor flow of personnel or materials.

9Aseptic processing and sterility assurance

Personnel were observed manually contacting the inner surface of a sterile container or closure and manually touching a sterile product contact surface.

10Aseptic processing and sterility assurance

Personnel performed aseptic manipulations with exposed hair or skin.

11Contamination control

Microbial contamination was present in the ISO 5 area.

12Contamination control

Contamination was observed in your areas adjacent to production areas.

13Cleaning validation

Use of cleaning and disinfecting agents that may leave residues or not adequately rinsing such agents from containers, closures, or equipment that come into direct contact with drug products.

14Aseptic processing and sterility assurance

Biological indicators were not used to verify the adequacy of the sterilization cycle.

About this record

Extracted automatically from the document US FDA published on 2026-10-01. The source is available at the link above.

This is a record of that moment. Inspection findings are usually followed by the company's response and corrective action, but this page does not know how that turned out. Do not read it as the current state; check the regulator's official announcements for the latest status.

Translation and classification are automated and may differ in nuance from the source.

Houston Rx LLC company profile — full historyAll US FDA findings US FDA documents, 2026 Go to Findings search
Weekly Newsletter

Get new findings like these every Monday

Every Monday we email the week's new findings and actions from the FDA, EMA, Health Canada and MFDS. Each one links to its record on our site, where you'll find the regulator's original document. We'll also let you know when the site gains new features. Unsubscribe any time with one click.

See recent findings first

Sent every Monday · a confirmation email follows when you subscribe · unsubscribe from the footer of any email.