The duration of each aspect of aseptic preparation and processing should be minimized and limited to a defined and validated maximum time, including:

i. The holding time between equipment, component, and container cleaning, drying and sterilisation.

ii. The holding time for sterilised equipment, components, and containers before use and during filling/assembly.

iii. The holding time for a decontaminated environment, such as the RABS or isolator before use.

iv. The time between the start of the preparation of a product and its sterilisation or filtration through a microorganism-retaining filter (if applicable), through to the end of the aseptic filling process. There should be a maximum permissible time for each product that takes into account its composition and the prescribed method of storage.

v. The holding time for sterilised product prior to filling.

vi. The aseptic processing time.

vii. The filling time.