EU · EudraLex Vol.4
EU GMP Annex 1 8.65
8. Production and Specific Technologies › Moist heat sterilisation
조항 원문
Validation of the sterilisation of fluids loads in a superheated water autoclave should include temperature mapping of the entire load and heat penetration and reproducibility studies. All parts of the load should heat up uniformly and achieve the desired temperature for the specified time. Routine temperature monitoring probes should be correlated to the worst case positions identified during the qualification process.