8. Production and Specific Technologies › Dry heat sterilisation

조항 원문

Dry heat sterilisation/depyrogenation tunnels should be configured to ensure that airflow protects the integrity and performance of the grade A sterilising zone by maintaining appropriate pressure differentials and airflow through the tunnel. Air pressure difference profiles should be assessed. The impact of any airflow change should be assessed to ensure the heating profile is maintained. All air supplied to the tunnel should pass through at least a HEPA filter and periodic tests (at least biannually) should be performed to demonstrate air filter integrity. Any tunnel parts that come into contact with sterilised components should be appropriately sterilised or disinfected. Critical process parameters that should be considered during validation and/or routine processing should include, but are not limited to:

i. Belt speed or dwell time within the sterilising zone.

ii. Temperature – minimum and maximum temperatures.

iii. Heat penetration of the material/article.

iv. Heat distribution/uniformity.

v. Airflows determined by air pressure difference profiles correlated with the heat distribution and penetration studies.

본문은 원문(영어)입니다. 국문 번역은 준비 중입니다.