12. VALIDATION

조항 원문

An exception can be made for retrospective validation for well established processes that have been used without significant changes to API quality due to changes in raw materials, equipment, systems, facilities, or the production process. This validation approach may be used where:

(1) Critical quality attributes and critical process parameters have been identified;

(2) Appropriate in-process acceptance criteria and controls have been established;

(3) There have not been significant process/product failures attributable to causes other than operator error or equipment failures unrelated to equipment suitability; and

(4) Impurity profiles have been established for the existing API.

본문은 원문(영어)입니다. 국문 번역은 준비 중입니다.

출처: International Council for Harmonisation (ICH) · © ICH. Per the legal notice in each guideline, the document may be used, reproduced and distributed provided ICH's copyright is acknowledged; any adaptation or translation must be labelled as such and must not imply ICH endorsement. · 수집일 2026-11-15