본문 바로가기

EU · EudraLex Vol.4

EU GMP Annex 1 8.101

8. Production and Specific Technologies › Form-Fill-Seal (FFS)

조항 원문

Critical process parameters for FFS should be determined during equipment qualification and should include, but are not limited to:

i. Settings for uniform package dimensions and cutting in accordance with validated parameters.

ii. Setting, maintenance and monitoring of validated forming temperatures (including pre-heating and cooling), forming times and pressures as relevant.

iii. Setting, maintenance and monitoring of validated sealing temperatures, sealing temperature uniformity across the seal, sealing times and pressures as relevant.

iv. Environmental and product temperature.

v. Batch-specific testing of package seal strength and uniformity.

vi. Settings for correct filling volumes, speeds and uniformity.

vii. Settings for any additional printing (batch coding), embossing or debossing to ensure that unit integrity is not compromised.

viii. Methods and parameters for integrity testing of filled containers (see paragraph 8.22).

본문은 원문(영어)입니다. 국문 번역은 준비 중입니다.

출처: European Commission, DG SANTE · © European Union. Reuse is authorised provided the source is acknowledged (Commission Decision 2011/833/EU on the reuse of Commission documents). · 수집일 2026-11-15