The controls identified during qualification of BFS should be in alignment with the site’s CCS. Aspects to be considered include but are not limited to:

i. Determination of the boundaries of the critical zone.

ii. Environmental control and monitoring, both of the machine and the background in which it is placed.

iii. Personnel gowning requirements.

iv. Integrity testing of the product filling lines and filtration systems (as relevant).

v. Duration of the batch or filling campaign.

vi. Control of polymer granulate, including distribution systems and critical extrusion temperatures.

vii. Cleaning-in-place and sterilisation-in-place of equipment as necessary.

viii. Machine operation, settings and alarm management (as relevant).