EU · EudraLex Vol.4
EU GMP Annex 1 8.115
8. Production and Specific Technologies › Blow-Fill-Seal
조항 원문
Critical process parameters for BFS should be determined during equipment qualification and should include, but are not limited to:
i. Clean-in-place and sterilisation-in-place of product pipelines and filling needles (mandrels).
ii. Setting, maintenance and monitoring of extrusion parameters, including temperature, speed and extruder throat settings for parison thickness.
iii. Setting, maintenance and monitoring of mould temperatures, including rate of cooling where necessary for product stability.
iv. Preparation and sterilisation of ancillary components added to the moulded unit, e.g. bottle caps.
v. Environmental control, cleaning, sterilisation and monitoring of the critical extrusion, transfer and filling areas as relevant.
vi. Batch-specific testing of package wall-thickness at critical points of the container.
vii. Settings for correct filling volumes, speeds and uniformity.
viii. Settings for any additional printing (batch coding), embossing or debossing to ensure that unit integrity and quality is not compromised.
ix. Methods and parameters for integrity testing of 100% of all filled containers (see paragraph 8.22).
x. Settings for cutters or punches used to remove waste plastic surrounding filled units (flash removal).
본문은 원문(영어)입니다. 국문 번역은 준비 중입니다.
출처: European Commission, DG SANTE · © European Union. Reuse is authorised provided the source is acknowledged (Commission Decision 2011/833/EU on the reuse of Commission documents). · 수집일 2026-11-15